PharmaPure®+Precision+Pump+Tubing
Fournisseur:
Avantor Fluid Handling
Description:
No need to worry about the heat - use for applications up to 460 °F.
Numéro de catalogue:
(BOSSBS-5504R-A680)
Fournisseur:
Bioss
Description:
Tumor suppressor serine/threonine-protein kinase involved in mTORC1 signaling and post-transcriptional regulation. Phosphorylates FOXO3, ERK3/MAPK6, ERK4/MAPK4, HSP27/HSPB1, p53/TP53 and RHEB. Acts as a tumor suppressor by mediating Ras-induced senescence and phosphorylating p53/TP53. Involved in post-transcriptional regulation of MYC by mediating phosphorylation of FOXO3: phosphorylation of FOXO3 leads to promote nuclear localization of FOXO3, enabling expression of miR-34b and miR-34C, 2 post-transcriptional regulators of MYC that bind to the 3'UTR of MYC transcript and prevent MYC translation. Acts as a negative regulator of mTORC1 signaling by mediating phosphorylation and inhibition of RHEB. Part of the atypical MAPK signaling via its interaction with ERK3/MAPK6 or ERK4/MAPK4: the precise role of the complex formed with ERK3/MAPK6 or ERK4/MAPK4 is still unclear, but the complex follows a complex set of phosphorylation events: upon interaction with atypical MAPK (ERK3/MAPK6 or ERK4/MAPK4), ERK3/MAPK6 (or ERK4/MAPK4) is phosphorylated and then mediates phosphorylation and activation of MAPKAPK5, which in turn phosphorylates ERK3/MAPK6 (or ERK4/MAPK4). Mediates phosphorylation of HSP27/HSPB1 in response to PKA/PRKACA stimulation, inducing F-actin rearrangement.
UOM:
1 * 100 µl
Numéro de catalogue:
(BOSSBS-5504R-A555)
Fournisseur:
Bioss
Description:
Tumor suppressor serine/threonine-protein kinase involved in mTORC1 signaling and post-transcriptional regulation. Phosphorylates FOXO3, ERK3/MAPK6, ERK4/MAPK4, HSP27/HSPB1, p53/TP53 and RHEB. Acts as a tumor suppressor by mediating Ras-induced senescence and phosphorylating p53/TP53. Involved in post-transcriptional regulation of MYC by mediating phosphorylation of FOXO3: phosphorylation of FOXO3 leads to promote nuclear localization of FOXO3, enabling expression of miR-34b and miR-34c, 2 post-transcriptional regulators of MYC that bind to the 3'UTR of MYC transcript and prevent MYC translation. Acts as a negative regulator of mTORC1 signaling by mediating phosphorylation and inhibition of RHEB. Part of the atypical MAPK signaling via its interaction with ERK3/MAPK6 or ERK4/MAPK4: the precise role of the complex formed with ERK3/MAPK6 or ERK4/MAPK4 is still unclear, but the complex follows a complex set of phosphorylation events: upon interaction with atypical MAPK (ERK3/MAPK6 or ERK4/MAPK4), ERK3/MAPK6 (or ERK4/MAPK4) is phosphorylated and then mediates phosphorylation and activation of MAPKAPK5, which in turn phosphorylates ERK3/MAPK6 (or ERK4/MAPK4). Mediates phosphorylation of HSP27/HSPB1 in response to PKA/PRKACA stimulation, inducing F-actin rearrangement.
UOM:
1 * 100 µl
Numéro de catalogue:
(LENZ05586100)
Fournisseur:
Lenz Laborglas GmbH & CO.KG
Description:
Raccordements d'eau avec filetage GL 18, PP (écrou à douille R 3/4"), NBR (joints, 15×3 mm, 10×3 mm)
UOM:
1 * 1 ST
Fournisseur:
BOCHEM
Description:
These non serrated precision forceps are available in pure stainless steel or with PTFE coating.
Numéro de catalogue:
(PEAK60-0007)
Fournisseur:
PEAK SCIENTIFIC
Description:
The Precision Zero Air generators are designed specifically to supply clean, dry, hydrocarbon-free air to be used as flame support gas for GC at both standard and trace detection limits.
UOM:
1 * 1 ST
Fournisseur:
KLS Martin Group
Description:
Water jet pistol available individually or with a complete set.
Fournisseur:
PEAK SCIENTIFIC
Description:
The smallest hydrogen generator for GC-FID, Precision hydrogen SL has been developed to offer a streamlined laboratory-grade hydrogen gas solution for GC flame detectors at a purity of 99,9995%. Precision hydrogen SL is safe, simple to use, easy to maintain and takes up minimal bench space.
Numéro de catalogue:
(SCOT292500101)
Fournisseur:
DWK Life Sciences
Description:
Pompe à jet d'eau en polypropylène.
UOM:
1 * 1 ST
Fournisseur:
VWR Collection
Description:
Rack, Test tube, VWR®, Portoir pour tubes à essai en acier inoxydable pour un maximum de 15 tubes. Des bains en acier inoxydable de 6 litres peuvent accueillir 1 portoir, Acier inoxydable, Pour tubes Ø: 10 - 13 mm
Numéro de catalogue:
(24989.202)
Numéro de catalogue:
(BOSSBS-0018M)
Fournisseur:
Bioss
Description:
Insulysin was identified nearly a century ago as an enzyme responsible for the degradation of insulin in cells, although the precise interactions between insulin and insulysin remain elusive. Human insulysin was cloned in 1988, and shown to be a 118 kDa protein that exists primarily as a homodimer, and perhaps also complexed with other molecules. The sequence is well conserved between humans, rats and mice, and the antibody recognizes these species. Insulysin is a metalloproteinase of the clan ME, family M16, which contains an active site HxxEH, a reversal of the canonical HExxH zinc binding motif. Considered a zinc metalloproteinase, the activity of insulysin can be blocked with EDTA or 1-10 phenanthroline. In addition to the active metalloproteinase domain, insulysin contains a second metalloproteinase site which is considered catalytically inactive, and is thought to assist in substrate binding. Insulysin is most closely related to the bacterial proteinase pitrilysin, (the human orthologue of which appears to be MPRP1) and the mammalian proteinsae nardilysin. Generally thought to be a cytoplasmic protein, insulysin has been isolated from many different tissues and cell lines, and can degrade intact insulin, insulin B chain, glucagon, denatured hemoglobin, alpha amyloid protein, TGF alpha and amylin. Recent work implicates insulysin in clearing beta amyloid plaques from the brain, and has generated much interest in Alzheimer’s disease research. The pH optimum for insulysin is basic, pH 8.5, which also distinguishes it from other metalloproteinases. Insulin degrading enzyme (IDE) has a preferential affinity for insulin such that the presence of insulin will inhibit IDE mediated degradation of other substrates. IDE degrades a variety of other peptides including atrial natriuretic peptide and amylin.
UOM:
1 * 100 µl
Fournisseur:
AMARELL, ARNO
Description:
Low hazard precision thermometers are used for special applications and suitable for government calibration.
Fournisseur:
PEAK SCIENTIFIC
Description:
These precision nitrogen trace generators produce "zero nitrogen" on demand from a compressed air source.
Fournisseur:
MEMMERT
Description:
Des étuves sous vide fiables, puissantes et à rendement énergétique élevé, avec des étagères thermiques réglables séparément, qui sont chauffées directement, ce qui garantit un contrôle précis de la température et grâce à la régulation numérique de la pression, la charge de la chambre est non seulement séchée à grande vitesse mais aussi de manière extrêmement délicate dans ces appareils robustes. Idéal pour le séchage des denrées alimentaires, des cosmétiques, des granulés, des montres, des livres, des cartes de circuits imprimés, des composants électroniques ou des moules à injection. Tous les modèles sont équipés d'une porte en verre de sécurité avec une vitre intérieure pare-balles et un écran extérieur anti-éclats. Le boîtier extérieur est en acier inoxydable texturé tandis que la chambre intérieure est en acier inoxydable de haute qualité (DIN 1.4404) soudé hermétiquement.
Fournisseur:
VWR Collection
Description:
Ces fermetures sont adaptées aux tubes à essai et tubes de culture.
Appel de prix
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Ces articles ne peuvent être ajoutés au Panier. Veuillez contacter votre service client ou envoyer un e-mail à vwr.be@vwr.com
Une documentation supplémentaire peut être nécessaire pour l'achat de cet article. Un représentant de VWR vous contactera si nécessaire.
Ce produit a été bloqué par votre organisation. Contacter votre service d'achat pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Les produits marqués de ce symbole ne seront bientôt plus disponibles - vente jusqu'à épuisement de stock. Des alternatives peuvent être disponibles en recherchant le code article VWR indiqué ci-dessus. Si vous avez besoin d'une assistance supplémentaire, veuillez contacter notre Service Clientèle au 016 385 011.
|
|||||||||