Single-use+Temperature+Sensor
Fournisseur:
AAT BIOQUEST INC
Description:
Gentamicin is widely used for treating tuberculosis and Gram-negative infections and is particularly useful in neonatal intensive care units. Fluorophore-tagged drugs, such as gentamicin-Texas Red (GTTR) conjugates, have been used to identify drug trafficking routes across the BLB and into hair cells, and specifically in the cochlea - the sensory organ responsible for hearing. Identifying the mechanisms involved in the intracochlear trafficking of ototoxic drugs to hair cells is of fundamental as well as clinical importance. Texas Red-gentamicin conjugate (GTTR) provides researchers a valuable tool to study the cellular uptake, kinetics and distribution of gentamicin through fluorescence techniques, such as fluorescence microscopy, fluorescence correlation spectroscopy, single molecule spectroscopy. The TR fluorophore can be conveniently excited from 500-600 nm, with an emission maximum centered around 610 nm. Acute nephrotoxicity and permanent ototoxicity are serious side-effects that increase patient morbidity, or induce permanent auditory and vestibular deficits. Several approaches have been used to study the intracellular mechanisms induced by ototoxic drugs. However, ototoxic drugs must first cross the blood-labyrinth barrier (BLB) before entering sensory hair cells to exert their cytotoxic effect that leads to hearing loss and deafness. The BLB is similar to the blood-brain barrier (BBB), and is composed of tight junction-coupled endothelial and epithelial barrier layers that transport nutrients and ions from one side of the barrier to the other.
Fournisseur:
Restek
Description:
This heater cartridge and PRT sensor can be used with 5890 FID and split/splitless weldments.
Fournisseur:
JULABO GmbH
Description:
The DYNEO™ DD heating circulators are available in several bath combinations, with varying bath sizes. DYNEO is designed for internal as well as external applications. Operation and handling is easy using the large TFT colour display and the state of the art turn and push controller. The bath tanks are well insulated with a built-in coil for counter cooling. An integrated drain tap makes emptying the tank safe and clean.
Numéro de catalogue:
(PRSI33-414)
Fournisseur:
ProSci Inc.
Description:
Recognises a protein of 75 kDa, identified as mu heavy chain of human immunoglobulins. It does not cross-react with alpha (IgA), gamma (IgG), epsilon (IgE), or delta (IgD), heavy chains, T-cells, monocytes, granulocytes, or erythrocytes. Monomeric IgM is expressed as a membrane bound antibody on the surface of B cells and as a pentamer when secreted by plasma cells. IgM antibody is prominent in early immune responses to most antigens. Aberrant levels are associated with immune deficiency states, hereditary deficiencies, myeloma, Waldenstrom's macroglobulinemia, chronic infection and hepatocellular disease. This mAb is useful in the identification of leukemias, plasmacytomas, and certain non-Hodgkins lymphomas. The most common feature of these malignancies is the restricted expression of a single heavy chain class. Demonstration of clonality in lymphoid infiltrates indicates that the infiltrate is clonal and therefore malignant.
UOM:
1 * 1 EA
New Product
Fournisseur:
Heidolph Instruments GmbH & Co.KG
Description:
Transforme un agitateur magnétique en une station de travail pour des expériences multiples, améliorez la productivité de votre laboratoire; utilisez un simple agitateur à plaque chauffante pour réaliser des expériences multiples. Pour les expériences simples de chauffage/agitation ou les applications plus complexes telles que la synthèse, les concentrations, les extractions et les distillations. Prend en charge une large gamme d'instruments de laboratoire en verre standard tels que les flacons, les tubes à essai, les béchers et les flacons à fond rond. Une gamme d'inserts est disponible pour les petits flacons ou les flacons à fond rond de 250 ml.
Numéro de catalogue:
(PRSI33-344)
Fournisseur:
ProSci Inc.
Description:
It recognises an oncofetal glycoprotein with a single chain of 70 kDa, which is identified as alpha fetoprotein (AFP). This mAb is highly specific to AFP and shows no cross-reaction with other oncofetal antigens or serum albumin. The yolk sac and the liver produce AFP during fetal life. AFP expression in adults is often associated with hepatoma or teratoma. However, hereditary persistence of alpha-fetoprotein may also be found in individuals with no obvious pathology. The protein is thought to be the fetal counterpart of serum albumin, and the AFP and albumin genes are present in tandem in the same transcriptional orientation on chromosome 4. AFP is found in monomeric as well as dimeric and trimeric forms, and binds copper, nickel, fatty acids and bilirubin. The level of AFP in amniotic fluid is used to measure renal loss of protein to screen for spinal bifida and anencephaly.
UOM:
1 * 1 EA
New Product
Numéro de catalogue:
(UVPA97-0015-02)
Fournisseur:
UVP ULTRA VIOLET PRODUCTS
Description:
This digital UVX Radiometer is used with one of the three interchangeable sensors (ordered separately) for measuring 254, 365 and 302 nm UV wavelengths. Measurement of lamp irradiance is the most effective way to monitor the useful life of any UV light source.
UOM:
1 * 1 ST
Fournisseur:
MERCK PRODUCTION CHEMICALS
Description:
Sélection de gels de silice standardisés et modifiés de Merck, disponibles dans de nombreuses granulométries, fournis depuis une source unique et conçus pour la chromatographie. Les gels de silice standardisés sont fréquemment utilisés dans les processus de séparation, afin de purifier des composés précieux. En revanche, les gels de silice modifiés sont utilisés pour solutionner les problèmes de séparation qui n'ont pu être résolus à l'aide de silice non modifiée.
Fournisseur:
B. Braun
Description:
En acier inoxydable, embout Luer Lock en PP transparent. Les aiguilles stériles hypodermiques Sterican® à paroi fine et usage unique sont adaptées aux injections intramusculaires, sous-cutanées, intraveineuses, intraartérielles et autres injections spécifiques.
Fournisseur:
Mettler - Toledo
Description:
Redox buffer solutions are used for verification of all common redox sensors.
Fournisseur:
HAMILTON BONADUZ
Description:
Low bleed high temperature septa are designed for the lowest bleed possible at temperatures of up to 400 °C. They can be used in combination with Mass Spectrometers or in applications where septa bleed interferes with trace analysis. These septa are typically used for manual injection applications.
Numéro de catalogue:
(PRSI40-574)
Fournisseur:
ProSci Inc.
Description:
The three mammalian isoforms of TGF-β, TGF-β1, β2, β3, signal through the same receptor and elicit similar biological responses. They are multifunctional cytokines that regulate cell proliferation, growth, differentiation and motility as well as synthesis and deposition of the extracellular matrix. They are involved in various physiological processes including embryogenesis, tissue remodeling and would healing. They are secreted predominantly as latent complexes which are stored at the cell surface and in the extracellular matrix. The release of biologically active TGF-β isoform from a latent complex involves proteolytic processing of the complex and /or induction of conformational changes by proteins such as thrombospondin-1. The physiological role of TGF-β3 is still unknown but its expression pattern suggests a role in the regulation of certain development processes. Recombinant TGF-β3 is a 25.0 kDa protein composed of two identical 112 amino acid polypeptide chains linked by a single disulfide bond.Manufactured using all non-animal reagents.
UOM:
1 * 1 EA
Numéro de catalogue:
(PRSI33-342)
Fournisseur:
ProSci Inc.
Description:
Recognises a single chain glycoprotein of 70 kDa, identified as CD55 (also known as decay accelerating factor, DAF). This mAb was clustered in Kobe at the Sixth International Workshop on Human Leukocyte Differentiation Antigens as F429D-9 (N-L120). CD55/DAF is widely expressed on cells throughout the body including leukocytes, erythrocytes, epithelium, endothelium, and fibroblasts. It is a Glycosyl phosphatidylinositol anchored (GPI-anchored) member of the membrane bound complement regulatory proteins that inhibit autologous complement cascade activation. It prevents the amplification steps of the complement cascade by interfering with the assembly of the C3-convertases, C4b2a and C3bBb, and the C5-convertase, C4b2a3b and C3bBb3b. CD55 also serves as receptor for CD97 and for echovirus and Coxsackie B virus. Anti-CD55 can be used as marker for paroxysmal nocturnal hemoglobinuria (PNH).
UOM:
1 * 1 EA
New Product
Fournisseur:
VWR Collection
Description:
Cet instrument convivial et portable avec boîtier IP 67 solide offre une résolution et une précision élevées pour des mesures de pH, de mV, de conductivité et d'oxygène précises lors des applications de terrain (2 mesures simultanées uniquement). À utiliser avec la sortie USB étanche pour connexion à un ordinateur. Conforme aux BPL.
Numéro de catalogue:
(LBCP7522700)
Fournisseur:
LABCONCO
Description:
Benchtop freeze drying system, type 304 stainless steel with 12 ports, -75 °C. Ideal for the laboratory with occasional lyophilisation requirements, the Dry Ice Benchtop Freeze Dry System provides a simple, economical means of freeze-drying. It is equipped with a center well for dry ice and solvent that serves as a water vapour collector and doubles as a convenient pre-freezing bath. Flasks, serum bottles and ampules may be frozen by dipping and rotating them in the well. Chamber size 248 x222 mm
UOM:
1 * 1 ST
Numéro de catalogue:
(PRSI33-147)
Fournisseur:
ProSci Inc.
Description:
IgM is the first antibody generated in an immune response to an antigen. It is generally a pentamer with each of the five immunoglobulins linked together with disulfide bonds. In its pentamer form, it has a molecular mass of 970 kDa and 10 antigen binding sites (due to the large size of most antigens, not all binding sites can be filled simultaneously. IgM antibodies account for approximately 5%-10% of all the antibody in the body.<p>This mAb is specific for the human IgM heavy chain. It does not cross-react with other immunoglobulin heavy chains, T-cells, monocytes, granulocytes, or erythrocytes. IgM antibody is useful in the identification of certain cancer types. Some tumors express a single heavy chain class. Demonstration of clonality in lymphoid infiltrates indicates that the infiltrate is clonal and therefore malignant.
UOM:
1 * 1 EA
New Product
Appel de prix
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Ces articles ne peuvent être ajoutés au Panier. Veuillez contacter votre service client ou envoyer un e-mail à vwr.be@vwr.com
Une documentation supplémentaire peut être nécessaire pour l'achat de cet article. Un représentant de VWR vous contactera si nécessaire.
Ce produit a été bloqué par votre organisation. Contacter votre service d'achat pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Les produits marqués de ce symbole ne seront bientôt plus disponibles - vente jusqu'à épuisement de stock. Des alternatives peuvent être disponibles en recherchant le code article VWR indiqué ci-dessus. Si vous avez besoin d'une assistance supplémentaire, veuillez contacter notre Service Clientèle au 016 385 011.
|
|||||||||