chiral+technologies
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
Type de colonne: Colonne HPLC, CHIRALPAK® PSA, Acier inoxydable, Ø int.: 4,00 mm, Longueur: 50 mm, Granulométrie: 5 µm
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
Type de colonne: Colonne HPLC, CHIRALPAK® BSA, Acier inoxydable, Ø int.: 2,10 mm, Longueur: 50 mm, Granulométrie: 5 µm
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
Type de colonne: Colonne HPLC, CHIRALPAK® RSA, Acier inoxydable, Ø int.: 4,00 mm, Longueur: 50 mm, Granulométrie: 5 µm
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
These columns are packed with Daicel’s coated polysaccharide-based chiral stationary phases (CSPs) which are manufactured by physically coating the polysaccharide derivatives onto silica matrices. Due to this manufacturing process, a choice of mobile phase components is typically narrower than with immobilised columns in order to minimise damage to the CSPs.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
CHIRALPAK® QN-AX and CHIRALPAK® QD-AX are enantioselective weak anion-exchange (AX) HPLC columns. The chiral selectors for CHIRALPAK® QD-AX and CHIRALPAK® QN-AX anion exchange phases are based on complementary quinine (QN) and quinidine (QD) derivative selectors bonded to high efficiency 5 µm diameter spherical silica. The structure of these selectors is such that a tertiary amine is located in a three-dimensional cleft surrounded by additional hydrogen binding sites and a large aromatic group. This combination provides excellent separations of chiral acids.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
CHIRALPAK®, Immobilized polysaccharide, Ø int.: 4,6 mm, Longueur: 50 mm, Granulométrie: 10 µm
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
These protein-based columns are suitable for separation of basic compounds. These columns function entirely in the reversed phase chromatographic mode, using buffers with low organic modifier content and at moderate pH values.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
The CHIRALPAK® ZWIX columns were developed for separation of a great variety of zwitterionic molecules, specifically, for separation of underivatised amino acids.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
Pour la séparation de composés chiraux acides contenant des groupes d'acides carboxyliques, phosphoniques, phosphiniques, phosphoriques ou sulphoniques. Dans certains cas, des composés acides comme les phénols peuvent être séparés.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
CROWNPAK® CR(+) and CR(-) contain a chiral crown ether as a chiral selector, which is coated onto a 5 µm silica support. CROWNPAK® selectors are mainly used to separate chiral amino acids and other small molecules with primary amine groups. The elution order of the enantiomers can be reversed when necessary.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
When a material is in a state that the temperature and the pressure exceed the critical point, it becomes a supercritical fluid. In this phase, the density of gas and liquid becomes the same.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
When a material is in a state that the temperature and the pressure exceed the critical point, it becomes a supercritical fluid. In this phase, the density of gas and liquid becomes the same.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
These columns are packed with Daicel’s coated polysaccharide-based chiral stationary phases (CSPs) which are manufactured by physically coating the polysaccharide derivatives onto silica matrices. Due to this manufacturing process, a choice of mobile phase components is typically narrower than with immobilised columns in order to minimise damage to the CSPs.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
These protein-based columns are suitable for separation of basic, acidic and non-protolytic compounds. These columns function entirely in the reversed phase chromatographic mode, using buffers with low organic modifier content and at moderate pH values.
Fournisseur:
CHIRAL TECHNOLOGIES
Description:
These protein-based columns are suitable for separation of acidic and non-protolytic compounds. These columns function entirely in the reversed phase chromatographic mode, using buffers with low organic modifier content and at moderate pH values.
Fournisseur:
MACHEREY-NAGEL
Description:
Silica based phases for HPLC enantiomer separation in which CHIRAL-1 seperation is based on ligand exchange and CHIRAL-2 or CHIRAL-3 on charge-transfer and further interactions as well as on steric effects.
Appel de prix
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l' est toujours affiché et vous avez besoin d'aide, s'il vous plaît appelez-nous au 016 385 011
Ces articles ne peuvent être ajoutés au Panier. Veuillez contacter votre service client ou envoyer un e-mail à vwr.be@vwr.com
Une documentation supplémentaire peut être nécessaire pour l'achat de cet article. Un représentant de VWR vous contactera si nécessaire.
Ce produit a été bloqué par votre organisation. Contacter votre service d'achat pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Les produits marqués de ce symbole ne seront bientôt plus disponibles - vente jusqu'à épuisement de stock. Des alternatives peuvent être disponibles en recherchant le code article VWR indiqué ci-dessus. Si vous avez besoin d'une assistance supplémentaire, veuillez contacter notre Service Clientèle au 016 385 011.
|
|||||||||