Masterflex+Single-use
Fournisseur:
WTW ONLINE
Description:
The special design of the process line electrodes makes them close to optimal in their accuracy, stability, speed and longevity to liquid electrolyte electrodes. For the use in pipelines, they can be installed into the replacement fitting CHEMtrac 830 M.
Numéro de catalogue:
(PRSI31-073)
Fournisseur:
ProSci Inc.
Description:
The scaffolding protein is the main component of the caveolae plasma membranes found in most cell types. The protein links integrin subunits to the tyrosine kinase FYN, an initiating step in coupling integrins to the Ras-ERK pathway and promoting cell cycle progression.The scaffolding protein encoded by this gene is the main component of the caveolae plasma membranes found in most cell types. The protein links integrin subunits to the tyrosine kinase FYN, an initiating step in coupling integrins to the Ras-ERK pathway and promoting cell cycle progression. The gene is a tumor suppressor gene candidate and a negative regulator of the Ras-p42/44 MAP kinase cascade. CAV1 and CAV2 are located next to each other on chromosome 7 and express colocalizing proteins that form a stable hetero-oligomeric complex. By using alternative initiation codons in the same reading frame, two isoforms (alpha and beta) are encoded by a single transcript from this gene.
UOM:
1 * 1 EA
Numéro de catalogue:
(PRSI90-398)
Fournisseur:
ProSci Inc.
Description:
CD68 is a single-pass type I membrane protein which belongs to the LAMP family. CD68 is highly expressed by blood monocytes and tissue macrophages. It is also expressed in lymphocytes, fibroblasts and endothelial cells and in many tumour cell lines which could allow them to attach to selectins on vascular endothelium, facilitating their dissemination to secondary sites. CD68 plays a role in phagocytic activities of tissue macrophages, both in intracellular lysosomal metabolism and extracellular cell-cell and cell-pathogen interactions. It is a commonly used marker for macrophages. However, a number of studies have shown that CD68 antibodies react with other hematopoietic and non-hematopoietic cell types, suggesting that CD68 may not be a macrophage-specific antigen. CD68 binds to tissue- and organ-specific lectins or selectins, allowing homing of macrophage subsets to particular sites. Rapid recirculation of CD68 from endosomes and lysosomes to the plasma membrane may allow macrophages to crawl over selectin-bearing substrates or other cells.
UOM:
1 * 1 EA
Fournisseur:
Cytiva
Description:
Les écrans d'enregistrement luminescent capturent les images latentes produites par les radiations ionisantes (rayons X, émissions β et γ provenant des isotopes tels que <sup>14</sup>C, <sup>3</sup>H, <sup>125</sup>I, <sup>131</sup>I, <sup>32</sup>P, <sup>35</sup>S, <sup>33</sup>P, etc.). Lors de la stimulation induite par laser, la quantité de lumière émise à partir de l'écran d'enregistrement luminescent est proportionnelle à la quantité de radioactivité dans l'échantillon. L'image numérique résultante permet une quantification des différences subtiles d'intensité du signal sur une large plage dynamique à l'aide de systèmes d'imagerie d'enregistrement luminescent tels que Typhoon, Storm et PhosphorImager. En règle générale, le temps d'exposition est réduit de 50% à 90% par rapport à un film traditionnel pour une exposition équivalente. Les images de qualité publication sont souvent obtenues en une seule exposition. Elles sont réutilisables et ne sont pas détériorées par l'exposition répétée aux niveaux de radioactivité du laboratoire.
Fournisseur:
HAMILTON BONADUZ
Description:
Electrodes for special laboratory applications such as microbiological samples, serum, flat surfaces, small volumes, and samples containing fats and proteins.
Numéro de catalogue:
(BDAM305901)
Fournisseur:
BD Medical
Description:
Aiguille hypodermique de protection, amovible, à usage unique, verrou en acier inoxydable. L'aiguille hypodermique à protection BD SafetyGlide™ est un dispositif de sécurité basé sur des aiguilles qui peut être utilisé avec des seringues traditionnelles de toute taille. L'aiguille amovible s'adapte à des seringues traditionnelles de toute taille, ce qui contribue à faciliter la normalisation et la réduction des SKU.
UOM:
1 * 500 ST
Numéro de catalogue:
(710-2260)
Fournisseur:
INTERSCIENCE
Description:
easySpiral Dilute® offre 2 équipements en un: dilueur automatique et ensemenceur. Il permet de faire 5 dilutions en série au 1/10ͤ , ainsi que l'ensemencement sur 1 seule boîte de Petri avec une détection de 30 à 1x10<sup>12</sup> CFU/ml. Contrôle par microprocesseur, et possibilité d'utiliser des boîtes de Petri de diamètre: 55 mm, 90 mm et 150 mm. Avec mélange de l'échantillon avant dilution/ensemencement, et un programme de nettoyage mensuel. Ensemencement successif avec le même échantillon: 20 boîtes de Petri (50 μl).
UOM:
1 * 1 ST
Fournisseur:
Merck Millipore (Novagen)
Description:
Le kit BugBuster® Plus Lysonase™ inclut le réactif d'extraction de protéines BugBuster et le réactif de biotraitement Lysonase, un mélange optimisé et prêt à l'emploi de rLysozyme™ et de nucléase Benzonase®. Cette puissante association de deux réactifs permet une récupération maximale des protéines solubles actives dans les bactéries à Gram négatif et à Gram positif. Les réactifs BugBuster et rLysozyme lysent efficacement les cellules bactériennes tandis que la Benzonase dégrade les acides nucléiques pour faciliter le traitement en aval. Requiert 5 ml de BugBuster et 10 µl de Lysonase par gramme de pâte cellulaire. Les kits fournissent suffisamment de réactifs pour l'extraction de protéines dans 20 ou 100 g de pâte cellulaire.
Numéro de catalogue:
(ICNA0855676)
Fournisseur:
MP Biomedicals
Description:
This product is the lyophilized powder of horseradish peroxidase (HRP)-conjugated goat IgG fraction to rabbit IgG (whole molecule) and buffer salts. Anti-Human IgG is developed in goat using IgG from pooled normal human serum as the immunogen. Whole antiserum is fractionated and then further purified by ion exchange chromatography to provide the IgG fraction of antiserum. This fraction is essentially free of other goat serum proteins. Specificity for human IgG is determined by immunoelectrophoresis (IEP) versus purified human IgA, IgG, IgM, Bence Jones kappa, and Bence Jones lambda myeloma proteins.Identity and purity of the antibody is established by immunoelectrophoresis (IEP), prior to conjugation. Electrophoresis of the antibody preparation followed by diffusion versus anti-goat IgG and anti-goat whole serum result in single arcs of precipitation in the gamma region.
UOM:
1 * 2 mL
Numéro de catalogue:
(PRSI33-147)
Fournisseur:
ProSci Inc.
Description:
IgM is the first antibody generated in an immune response to an antigen. It is generally a pentamer with each of the five immunoglobulins linked together with disulfide bonds. In its pentamer form, it has a molecular mass of 970 kDa and 10 antigen binding sites (due to the large size of most antigens, not all binding sites can be filled simultaneously. IgM antibodies account for approximately 5%-10% of all the antibody in the body.<p>This mAb is specific for the human IgM heavy chain. It does not cross-react with other immunoglobulin heavy chains, T-cells, monocytes, granulocytes, or erythrocytes. IgM antibody is useful in the identification of certain cancer types. Some tumors express a single heavy chain class. Demonstration of clonality in lymphoid infiltrates indicates that the infiltrate is clonal and therefore malignant.
UOM:
1 * 1 EA
New Product
Fournisseur:
Integra
Description:
Ces systèmes sont utilisés pour l'aspiration, l'extraction ou la filtration des liquides biologiques ou chimiques, proprement et efficacement. Toutes les fonctions nécessaires sont intégrées dans cet appareil compact. Grâce à son fonctionnement avec un bouton unique, le dispositif est toujours prêt à l'emploi.
Numéro de catalogue:
(460-2116)
Fournisseur:
Cole Parmer
Description:
En aluminium anodisé, l×p×h (mm): 75×95×50 (sauf 460-0017 et 460-0014), ce qui permet de les combiner à volonté.
UOM:
1 * 1 ST
Fournisseur:
LGC Standards PROMOCHEM
Description:
Ces solutions sont destinées à être utilisées comme matériau de référence certifié ou comme étalon pour l'analyse de cet élément dans les produits pétroliers ou d'autres matrices organiques au moyen de la spectroscopie d'émission optique avec plasma à couplage inductif (ICP-OES), de la spectrométrie de masse avec plasma à couplage inductif (ICP-MS), de la spectroscopie d'émission atomique avec électrode à disque rotatif (RDE-AES), de la spectroscopie d'absorption atomique dans la flamme ou le four (AA ou GFAA) et d'autres techniques d'analyse élémentaire.
Numéro de catalogue:
(IKAAU078310)
Fournisseur:
IKA
Description:
The magic LAB® is a unique and multi-functional small-scale laboratory machine. It is designed for mixing, dispersing, wet milling and incorporation of powders into liquids. The magic LAB® is most frequently used for the development of new products or for optimising of existing process techniques, particularly in the chemical, cosmetic, pharmaceutical and food industries. It is an ideal machine for continuous, circulating and batch processing with interchangeable modules. Many work parameters of the magic LAB® are identical to those of the IKA 2000 inline production machines: UTL, DR, CMS, MHD, MK and MKO. Therefore, the magic LAB® ensures a reliable scale-up by offering the possibility to work with the same method from formulation development to mass production. The basic in-line machine is equipped with the single-stage dispersing module ULTRA-TURRAX® UTL. It is best suited for batch applications and can be adapted for the manufacturing of dispersions from coarse to fine. Compared to a conventional stirrer, the mixing time is reduced by up to 50%. Depending on the application, the basic unit can be modified quickly with different working modules.
UOM:
1 * 1 ST
Numéro de catalogue:
(PRSI4969)
Fournisseur:
ProSci Inc.
Description:
TREX1 Antibody: Trex1 is the major human 3' to 5' exonuclease which is required for checkpoint signaling after DNA damage. It is ubiquitously expressed, binds to single stranded DNA coated with replication protein A that accumulates at sites of DNA damage and recruits the ataxia telangiectasia and Rad3 related protein (ATR), a checkpoint kinase, to sites of DNA damage and replication stress. Trex1 is required for ATR expression. This gene uses two different open reading frames. The upstream ORF encodes proteins which interact with ATR and localize to intranuclear foci induced by DNA damage and are essential components of the DNA damage checkpoint. The downstream ORF encodes proteins with 3' to 5' exonuclease activity and may be a subunit of human DNA polymerase III. Multiple transcript variants encoding different isoforms have been found. Mutations in this gene result in Aicardi-Goutieres syndrome, chilblain lupus, and Cree encephalitis.
UOM:
1 * 1 EA
Fournisseur:
Avantor Fluid Handling
Description:
Ensure optimum performance from your Masterflex® pump.
![]()
Appel de prix
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'
![]()
Le stock de cet article est limité mais peut être disponible dans un entrepôt proche de vous. Merci de vous assurer que vous êtes connecté sur le site afin que le stock disponible soit affiché. Si l'
![]()
Ces articles ne peuvent être ajoutés au Panier. Veuillez contacter votre service client ou envoyer un e-mail à vwr.be@vwr.com
Une documentation supplémentaire peut être nécessaire pour l'achat de cet article. Un représentant de VWR vous contactera si nécessaire.
Ce produit a été bloqué par votre organisation. Contacter votre service d'achat pour plus d'informations.
Le produit original n'est plus disponible. Le remplacement représenté est disponible
Les produits marqués de ce symbole ne seront bientôt plus disponibles - vente jusqu'à épuisement de stock. Des alternatives peuvent être disponibles en recherchant le code article VWR indiqué ci-dessus. Si vous avez besoin d'une assistance supplémentaire, veuillez contacter notre Service Clientèle au 016 385 011.
|
|||||||||